Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1991 1
1992 1
1997 1
2001 1
2002 1
2022 1
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

6 results

Results by year

Filters applied: . Clear all
Page 1
Analysis of mode switching algorithms in dual chamber pacemakers.
Israel CW. Israel CW. Pacing Clin Electrophysiol. 2002 Mar;25(3):380-93. doi: 10.1046/j.1460-9592.2002.00380.x. Pacing Clin Electrophysiol. 2002. PMID: 11990674 Review.
Similarly, fast return to tracking mode after ATA cessation seems preferable but requires algorithms to prevent mode oscillations. Sudden ventricular rate changes have to be avoided by rate smoothing functions, and an appropriate ventricular rate during nontracking mode ha …
Similarly, fast return to tracking mode after ATA cessation seems preferable but requires algorithms to prevent mode oscillations. Su …
Concurrent stimulation and sensing in bi-directional brain interfaces: a multi-site translational experience.
Ansó J, Benjaber M, Parks B, Parker S, Oehrn CR, Petrucci M, Gilron R, Little S, Wilt R, Bronte-Stewart H, Gunduz A, Borton D, Starr PA, Denison T. Ansó J, et al. J Neural Eng. 2022 Mar 31;19(2):10.1088/1741-2552/ac59a3. doi: 10.1088/1741-2552/ac59a3. J Neural Eng. 2022. PMID: 35234664 Free PMC article.
Key considerations for the configuration include (a) active instead of passive recharge, (b) sense-channel blanking in the amplifier, (c) high-pass filter settings, (d) tissue-electrode impedance mismatch management, (e) time-frequency trade-offs in the classifier, (f) alg …
Key considerations for the configuration include (a) active instead of passive recharge, (b) sense-channel blanking in the amplifier, …
[Mode-switching algorithms: programming and usefulness].
Israel CW. Israel CW. Herz. 2001 Feb;26(1):2-17. doi: 10.1007/pl00002003. Herz. 2001. PMID: 11258106 German.
MODE-SWITCHING ALGORITHMS: To achieve these aims, different mode-switching algorithms have been developed which all show specific disadvantages: reliable but slow response to atrial tachyarrhythmias, fast but unspecific switch to non-tracking mode, mode oscillations, incli …
MODE-SWITCHING ALGORITHMS: To achieve these aims, different mode-switching algorithms have been developed which all show specific disadvanta …
Neural activity in dorsolateral pontine nucleus of alert monkey during ocular following responses.
Kawano K, Shidara M, Yamane S. Kawano K, et al. J Neurophysiol. 1992 Mar;67(3):680-703. doi: 10.1152/jn.1992.67.3.680. J Neurophysiol. 1992. PMID: 1578251
On the other hand, the blurred images did not change the timing of the effect of blanking the visual scene on the responses of the neurons or eye movements. 6. ...The eye movements recorded at the same time showed signs of oscillation, and their temporal patterns we …
On the other hand, the blurred images did not change the timing of the effect of blanking the visual scene on the responses of the ne …
Failure of automatic mode switching: recognition and management.
Ellenbogen KA, Mond HG, Wood MA, Barold SS. Ellenbogen KA, et al. Pacing Clin Electrophysiol. 1997 Feb;20(2 Pt 1):268-75. doi: 10.1111/j.1540-8159.1997.tb06170.x. Pacing Clin Electrophysiol. 1997. PMID: 9058863
Failure to mode switch may also occur when the atrial signal periodically occurs in the atrial blanking period(s). In this article, we describe failure to mode switch in seven patients with paroxysmal supraventricular tachyarrhythmias after a Telectronics Meta DDDR 1254 de …
Failure to mode switch may also occur when the atrial signal periodically occurs in the atrial blanking period(s). In this article, w …
Dynamics of adaptation for vision with a stabilized image.
Saleh BE, Tulunay-Keesey U, Ver Hoeve JN, Hom M. Saleh BE, et al. J Opt Soc Am A. 1991 Jul;8(7):1172-81. doi: 10.1364/josaa.8.001172. J Opt Soc Am A. 1991. PMID: 1886009
When the increment is small, the pattern appears in its original phase (OP), large increments produce an apparent phase reversal (APR), and intermediate increments may yield an apparently blank field or an oscillation of the apparent phase. In the present series of studies …